  1. Using Romex is... against code? - DIY Home Improvement Forum

    Sep 14, 2021 · I bought some standard 12/2 Romex at Home Depot for some electrical work. Same stuff I've used my whole life. Moved to IL last year, and I am now finding out that using Romex is against …

  2. Running Romex to an outside mounted junction box and code

    Apr 19, 2023 · I reside in CT - Anyone know if I can run my indoor Romex wire through house wall into a metal junction box? From there I'll run Schedule 40 with THHN wire out to endpoints. Core question …

  3. Does wiring within a shed need to be in conduit ? | DIY Home ...

    Dec 29, 2022 · From what you are saying you already ran the circuit from the house to the shed in conduit and are wondering about the interior wiring. If that is the case, Romex is fine. You will need a …

  4. Conduit for wiring running thru concrete foundation?

    Dec 2, 2009 · I plan on running an outlet circuit to an exterior wall, and will have to go through concrete above grade. Are there any specific code requiremnents [NEC] with regard to the wire through …

  5. Does code permit romex in PVC conduit? - DIY Home Improvement …

    Oct 24, 2010 · Does code permit me to rough in a 2" PVC conduit from a sub panel in attached garage back into the basement? It would maybe be 15'. I will probably be insulating and rocking the garage …

  6. Can I run romex inside garage cabinets? - DIY Home Improvement Forum

    Nov 2, 2024 · Need to install some IKEA lower cabinets in an attached garage. Wall is drywall with 1/2” conduit on surface in the way of the cabinets. Can I just install a box on each end to terminate the …

  7. Romex Exposed in Barn? - DIY Home Improvement Forum

    Aug 13, 2022 · Good Evening, My question is can NM-B (Romex) be ran exposed in an open air pole barn ceiling for lighting circuits? The code requirements for my county is NEC 2020. I would run it in …

  8. Running ROMEX into Conduit - DIY Home Improvement Forum

    Oct 24, 2009 · How many circuits are you adding? A common solution here (which may not be technically code compliant, but is widely used and accepted) is to simply run the romex through …

  9. wiring garage - romex in conduit or no? - DIY Home Improvement Forum

    Jul 15, 2021 · Romex is not intended to be run in conduit unless the conduit is being used as a sleeve (such as to install an outlet on a basement concrete wall). If using conduit as an actual wiring method …

  10. Air Conditioning - Romex in flexible liquid tight | DIY Home ...

    Sep 5, 2015 · They use Romex NMD90 10/3 (Canadian version of Type NM-B) cable running from the main panel in basement to outside. There is a breaker outside (a grey box), then it runs to the air …